Frequency Analysis of Atrial Action Potential Alternans
Atrial Fibrillation Monday, October 21st, 2013Circulation: Arrhythmia and Electrophysiology: August 31, 2013
Background—Few clinical indices identify the propensity of patients to atrial fibrillation (AF) when not in AF. Repolarization alternans has been shown to indicate AF vulnerability, but is limited in its sensitivity to detect changes in action potential (AP) duration (APD), which may be subtle. We hypothesized that spectral analysis would be a more sensitive and robust marker of AP alternans and thus a better clinical index of individual propensity to AF than APD alternans.
Methods and Results—In 31 patients (12 persistent AF, 15 paroxysmal AF, 4 controls with no AF), we recorded left (n=27) and right (n=6) atrial monophasic APs during incremental pacing from cycle length 500 ms (120 beats per minute) to AF onset. Alternans was measured by APD and spectral analysis. At baseline pacing (median cycle length [1st, 3rd quartiles], 500 ms [500, 500]), APD alternans was detected in only 7 of 27 AF patients (no controls), whereas spectral AP alternans was detected in 18 of 27 AF patients (no controls; P=0.003); AP alternans was more prevalent in persistent than paroxysmal AF, and absent in controls (P=0.018 APD; P=0.042 spectral). Spectral AP alternans magnitude at baseline was highest in persistent AF, with modest rate-dependent amplification, followed by paroxysmal AF, with marked rate dependence, and undetectable in controls until just before induced AF. read more